The three audit levels, explained
Building audits in Canada are described by the levels in ASHRAE Standard 211. Each level builds on the one before, and the level you ask for decides the price, the report and which incentive or loan will accept it.
-
Level 1
Walk-through
A site visit and a review of the utility bills. It benchmarks the building and lists low-cost and no-cost measures.
- Where the building stands against similar ones
- A list of recommendations with estimated savings and cost
Use it when: You want a first look before spending on engineering.
-
Level 2
Energy survey and analysis
Where the energy goes, then the savings and cost of each practical measure, including operating and maintenance changes.
- Measures costed and ranked
- The major capital upgrades that need more engineering
Use it when: You are applying for an incentive or a retrofit loan. Most programs ask for this level.
-
Level 3
Detailed analysis
Everything in Level 2, plus an in-depth analysis of the cost and savings of the capital-intensive upgrades, often with monitoring and modelling.
- Investment-grade numbers for each big project
- Data to support a financing decision
Use it when: You are planning a major retrofit, such as a new plant or a deep envelope upgrade.
Level descriptions follow ASHRAE Standard 211, as summarised by efficiencyPEI (Level 1) and Efficiency Manitoba (Levels 2 and 3).
Which level do you need?
Pick by purpose| You want to… | Start with | Why |
|---|---|---|
| See where the building stands before spending on engineering | Level 1 | A walk-through and bill review benchmarks the building and lists low-cost and no-cost measures. |
| Apply for an incentive or a retrofit loan | Level 2 | Toronto’s Energy Retrofit Loans ask for Level 2 or equivalent; its Hi-RIS apartment loans, Level 2 or above. Check each program. |
| Decide on a major capital project | Level 3 | An in-depth analysis of the cost and savings of capital-intensive upgrades, often with monitoring and modelling. |
| Tune the systems you already have | Level 1 or 2, then retro-commissioning | Operating and maintenance changes are part of a Level 2 survey; some utilities fund retro-commissioning separately. |
Replacing boilers, chillers or rooftop units? What to do before you buy.
Who does the work
Engineering, not EnerGuideBuilding audits are engineering work, delivered by mechanical engineering firms and energy consultancies. Toronto’s retrofit loans ask for a feasibility study by “a qualified third party, such as a Professional Engineer (P.Eng), Certified Energy Manager (CEM) or equivalent” (toronto.ca).
Houses and small low-rise multi-unit buildings are rated under NRCan’s EnerGuide system instead. See apartments and condos for where the line falls, or AuditYourHome.ca if you own a house.
Ask every firm
- Which ASHRAE level does the price cover?And which sections of the report will you deliver? “Energy audit” alone can mean a two-hour walk-through or months of metering.
- Who signs the recommendations?A Professional Engineer or Certified Energy Manager, named on the report.
- What is in the report?Costed and ranked measures, estimated savings, and the major capital projects that need more engineering.
- Will you prepare any utility pre-approval?Many incentives need approval before the audit starts. Ask whether the firm files it, and when.
- What do you need from us?Utility bills, drawings, equipment lists, access to the plant rooms and the roof, and someone who knows the building.
- What happens after the report?Whether the firm helps with the incentive application, a capital plan or a follow-up measurement, and what that costs.
Common questions
What is ASHRAE Standard 211?
It is the Standard for Commercial Building Energy Audits from ASHRAE, the engineering society for heating, ventilation and air conditioning. It describes three levels of audit, each building on the one before, so an owner and an engineering firm can agree on what a quote covers.
Which audit level do most incentives and loans ask for?
Level 2 or above. The City of Toronto’s Energy Retrofit Loans ask for a facility description at ASHRAE Level 2 or equivalent, and its Hi-RIS apartment loans an energy assessment report at Level 2 or above. Check the program’s own page, because requirements differ.
Who performs a commercial energy audit?
Engineering firms and energy consultancies. Ask who signs the recommendations: a Professional Engineer (P.Eng.) or a Certified Energy Manager (CEM) is the usual answer. The EnerGuide licence that covers houses does not cover commercial buildings.
Can I start with Level 1 and move up later?
Yes. The levels build on each other, and a Level 1 walk-through is a common first look before spending on engineering. Ask the firm whether the work done at one level is credited if you move up to the next.
Sources
- ASHRAE: Standard 211, commercial building energy audits
- efficiencyPEI: ASHRAE Level 1 commercial energy audits
- Efficiency Manitoba: ASHRAE Level 2 and 3 audits
- City of Toronto: Energy Retrofit Loans
- City of Toronto: Hi-RIS apartment retrofit loans
Checked against these pages on October 8, 2026. Requirements change: confirm on the official page before you commission work.
Ready to ask for an audit?
Tell us the building and the level you have in mind, or ask us to help scope it.